Water meters, heat meters and radio remote reading systems, smart meters.
Wireless solutions IOT: radio applications.


G2 Colombia

 
  • VSF R1000.

    R1000 volumetric smart meter.

  • us

    Ultrasonic meter suitable for domestic and commercial outdoor applications, static measuring technology with no moving parts.
    Mod. US sizes DN 15 to DN 50 temperature class T30/T50, measuring range up to R500 Protection class: resin-coated IP68.

  • AFMS-PI.

    AFMS-PI.
    Super-Dry model temperature classes T30 and T50 (models up to R200 available on request).

  • RF-SLW.

    RF-SLW.
    AMR systems.

  • QDFM - PI.

    QDFM-, rollers protected, dry dial fully protected, measuring range R160 (models up to R315 on request), accuracy class 2, environmental class C, for turbid water.

  • Smart Meter

    UNI: protected rollers, FULLY PROTECTED DRY dial measuring range R315H-R160V, accuracy class 2, environmental class -25 +55°C, for turbid water.

Contatori per acqua a getto unico UNY MID

QDFM - Multi-jet water meters MULTY MID

QDFM - Multi-jet water meters MULTY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Multi-jet turbine straight reading meter, temperature classes T30 and T50.
  • Mod. QDFM-R200H,R63V, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R200H,R63V, for turbid water.
  • U0-D0: straight pipe not required upstream or downstream the meter.
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial.
  • All models are MID approved according to the current European Directive (module B+D) and in compliance with the norms EN 14154, ISO 4064 and OIML R49, reaching an R (Q3/Q1) ≤ 315H/63V.
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/ 2004 in compliance with European Directive 98/83 CE (Drinking Water Directive).
  • All models, on request, can be supplied pulsed output or preset for remote reading.

BFM / BCM / PFM - Multi-jet water meters MULTY MID

BFM / BCM / PFM - Multi-jet water meters MULTY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Multi-jet turbine straight reading meter.
  • Mod. BFM-R200H,R63V, WET dial, measuring range R200H,R63V, temperature classes T30 and T50, for clean water.
  • Mod. BCM-R80H,R40V, WET dial, measuring range R80H,R40V, temperature classes T70 and T90, for clean water.
  • Mod. PFM-R200H,R63V, LIQUID FILLED SEALED counter, measuring range R200H,R63V, temperature classes T30 and T50, for turbid water.
  • U0-D0: straight pipe not required upstream or downstream the meter.
  • All models are MID approved according to the current European Directive (module B+D) and in compliance with the norms EN 14154, ISO 4064 and OIML R49, reaching an R (Q3/Q1) ≤ 315H/63V.
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/ 2004 in compliance with European Directive 98/83 CE (Drinking Water Directive).

AFMS - Multi-jet water meters MULTY MID

AFMS - Multi-jet water meters MULTY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Mod. AFMS-PI-R160H, SUPER-DRY dial, measuring range R160H, environmental class C, for turbid and calcareous water, preset K=1 for inductive sensor IPS.
  • All models are MID approved according to the current European Directive (module B+D) and in compliance with the norms EN 14154, ISO 4064 and OIML R49, reaching an R (Q3/Q1) ≤200H.
  • Multi-jet turbine straight reading meter, temperature classes T30 and T50.
  • U0-D0: straight pipe not required upstream or downstream the meter.
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial.
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/ 2004 in compliance with with European Directive 98/83 CE (Drinking Water Directive).
  • All models, on request, can be supplied pulsed output or preset for remote reading.

QDFUPI / QDFU - Single-jet water meters UNY MID

QDFUPI / QDFU - Single-jet water meters UNY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Single-jet meter, direct reading, temperature classes T30 and T50
  • Mod. QDFUPI-R200H-R100V, DN 15 – 20, preset K=1 for inductive sensor IPS proof from magnetic intereferences, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R200H-R100V, for  turbid water
  • Mod. QDFUPI-R160H-R40V, DN 25 – 32 – 40, preset K=1 for inductive sensor IPS proof from magnetic intereferences, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R160H-R40V, for turbid water
  • Mod. QDFU-R200H-R100V, DN 15 – 20, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R200H-R100V, for  turbid water
  • Mod. QDFU-R160H-R40V, DN 25 – 32 – 40, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R160H-R40V, for turbid water
  • U0-D0: straight pipe not required upstream or downstream the meter
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial
  • All models are MID approved according to the European Directive 2004/22/CE (module B+D) and in compliance with the norms EN 14154 and OIML R49
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/2004
  • All models, on request, can be supplied pulsed output

BFU / BCU / PFU / PCU - Single-jet water meters UNY MID

BFU / BCU / PFU / PCU - Single-jet water meters UNY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Single-jet meter, direct reading
  • Mod. BFU-R100, WET DIAL, measuring range R100, temperature classes T30 and T50, for clean water
  • Mod. BFU-R160, WET DIAL, measuring range R160, temperature classes T30 and T50, for clean water
  • Mod. BCU-R80, WET DIAL, measuring range R80, temperature classes T70 and T90, for clean water
  • Mod. BCU-R160, WET DIAL, measuring range R160, temperature classes T70 and T90, for clean water
  • Mod. PFU-R100, LIQUID FILLED SEALED counter, measuring range R100, temperature classes T30 and T50, for turbid water
  • Mod. PFU-R160, LIQUID FILLED SEALED counter, measuring range R160, temperature classes T30 and T50, for turbid water
  • Mod. PCU-R80, LIQUID FILLED SEALED counter, measuring range R80, temperature classes T70 and T90, for turbid water
  • Mod. PCU-R160, LIQUID FILLED SEALED counter, measuring range R160, temperature classes T70 and T90, for turbid water
  • U0-D0: straight pipe not required upstream or downstream the meter
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial
  • All models are MID approved according to the European Directive 2004/22/CE (module B+D)  and in compliance with the norms EN 14154 and OIML R49, reaching an R (Q3/Q1) ≤ 200 H - ≤ 100 V                    
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/2004
  • All models, on request, can be supplied pulsed output or preset for remote reading

SFU / SCU / AFU / ACU - Single-jet water meters UNY MID

SFU / SCU / AFU / ACU - Single-jet water meters UNY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Single-jet meter, direct reading.
  • DRY dial for turbid and greatly calcareous waters (mod.SFU/SCU are fitted with 360° rotating dial for easy reading, and on request, available with or without lid, with or without glass wiping).
  • Mod. SFU-R80, DN 15 – 20, temperature classes T30 and T50, measuring range R80.
  • Mod. SCU-R80, DN 15 – 20, temperature classes T70 and T90, measuring range R80.
  • Mod. AFU-R80, DN 25 – 32 – 40, temperature classes T30 and T50, measuring range R80.
  • Mod. ACU-R80, DN 25 – 32 – 40, temperature classes T70 and T90, measuring range R80.
  • U0-D0: straight pipe not required upstream or downstream the meter.
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial.
  • All models are MID approved according to the current European Directive (module B+D) and in compliance with the norms EN 14154 and OIML R49, reaching an R (Q3/Q1) ≤ 125.
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/ 2004 in compliance with European Directive 98/83 CE (Drinking Water Directive).
  • All models, on request, can be supplied pulsed output or preset for remote reading: reed, M-Bus, LoraWan.

RPMAG - Electromagnetic flowmeter

RPMAG - Electromagnetic flowmeter.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Electromagnetic flowmeter consisting of a sensor and a transmitter.
  • The flowmeter is used to measure volumetric flowrate for conductive liquids and pulps.
  • Several output signals are available.
  • The main applications can be found in the following fields: chemical industry, power generation and distribution, mine, water treatment, paper industry, pharmaceutical industry, food and environmental protection.
  • The measurement is independent (>5μS/cm) of the density, viscosity, temperature, pressure and conductivity of the measured fluid.
  • Available, upon request, MID approved version.
  • Available, upon request, Lithium battery powered version.

SDF - Dual beam ultrasonic flowmeter MID

SDF - Dual beam ultrasonic flowmeter MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Dual beam ultrasonic technology for precise and ultra reliable metering:high accuracy starting from  25 l/h
  • Long-term stability of metrological performances
  • SDF-R500 mod. sizes from DN 50 to DN 300, temperature class T50, measuring range R500
  • Applications: waterworks, industrial and irrigation applications (with filtered water)
  • Battery powered with 10-year- working life
  • Multi line 9 digit LC display
  • Protection grade IP68
  • Instantaneous flow rate reading
  • U0-D0: the water meter can be installed in any position. The meter must be fill with water all the time; non special requirements for installation
  • All models are approved according to MID Directive 2004/22/CE (modules B+D), in compliance with EN 14154, OIML R49 and ISO 4064 norms
  • Body made of cast iron, with external epoxy painting, approved for use with potable water according to  D.M. 174 dated 6th april 2004
  • Pre-set for analogic output 4-20mA, forward flow. On request other options available: digital outputs open collector and dry contact

Inductive sensor G2-IPS model

Inductive sensor G2-IPS model.
  • INDUCTIVE sensor for pulse emitting, for multi and single jet meters, wet dial, liquid filled counter type, and fully protected dry dial model MID approved
  • The measurement of water delivered is done by conveying the flow rate into a rotation of a star index fitted with an amagnetic metallic sector and placed on the water meter
    dial; the electronic device detects the number of rotations and counts the volume of water delivered
  • The IPS sensor is equipped with a 5 wired cable, which can supply always 2 types of information: the pulse in high resolution detecting the flow direction, and the record data as serial format, with all the water meters main information and measuring results
  • The emitting device is completely waterproof and sealed (IP68) and its lining is made of a polymer, which is atossic and resistant to the normal working conditions
  • Totally proof from external interferences due to both static and changeable magnetic fields
  • Presetting on the liter star: K1
  • Self-diagnosis for good functioning and for tampering detection
  • Every sensor is fitted with antifraud system (against sensor removal and cable cutting)
  • RS 232 bidirectional output for serial data, data supplied: total volume, instantaneous flow rate, sensor serial number, functioning parameters, alerts
  • Battery power life more than 10 years in standard conditions
  • Detection of flow direction
  • Total volume counting is assured even in case of power cut
  • Precision 1pulse per litre for domestic use; for other applications, it can be set upon request

Reed switch sensor

Reed switch sensor
  • Impulse emitting device, REED switch sensor, for water meter with pre-arrangement for impulse-emitting device
  • Different values litres / pulse available (see data sheet in PDF)

Hall sensor

Hall sensor.
  • Multi and single jet meters, wet dial type, liquid filled sealed counter type and fully liquid sealed counter type, MID approved, equipped with a STATIC pulse emitting device, based on HALL sensors
  • 5 wired- Hall sensor, sensing and transmitting data to a consumption measuring system, which can detect the flow direction
  • The combined use of Hall sensors and a microprocessor enables to discover 2 types of tampering: - The sensor being removed from the meter; - The cable being severed and external magnets
  • In case of tampering, the Hall emitting device sends an electronic signal of alert, via one of its 5 wires, to an electronic counter, which records it immediately by signalling
  • The device is powered by a 15-year-long life lithium battery
  • The device guarantees an IP 68 protection class, making it suitable for pitch installations, where flood risk is high

LoRaWAN radio protocol module for fixed network and LoRa for walk-by/drive-by model G2-IPS-CLW

LoRaWAN radio protocol module for fixed network and LoRa for walk-by/drive-by model G2-IPS-CLW.
  • Inductive Sensor with LoRaWANTM radio module available in compact version for multiple and single jet water meters with wet dial, liquid filled counter type, fully protected dial, and super dry dial MID approved, preset for inductive sensor in K1. The measurement of the water is done by conveying the flow rate into a rotation of a star index fitted with an not magnetic metallic disk placed on the water meter dial.

868 wireless M-bus radio module module G2-IPS-C868WMB

868 wireless M-bus radio module module G2-IPS-C868WMB.
  • Inductive Sensor with 868 Mhz Wireless M-Bus available in compact version for multiple and single jet water meters with wet dial, liquid filled counter type, fully protected dial, and super dry dial MID approved, preset for inductive sensor in K1. The measurement of the water is done by conveying the flow rate into a rotation of a star index fitted with an amagnetic metallic disk placed on the water meter dial; the electronic device detects the number of rotations and counts the volume of water delivered.

NB-IoT radio module

NB-IoT radio module.

  • Inductive   Sensor   with   embedded   radio  module   NB-IoTavailable  in  compact  version  for  multiple  and  single  jet water  meters  with  wet  dial,  liquid  filled  counter  type,  fully protected dial, and super dry dial MID approved, preset for inductive sensor in K1. The measurement  of  the  water is done by  conveying  the  flow  rate  into  a  rotation  of a  star  index  fitted with  an  amagnetic  metallic  disk placed  on  the  water  meterdial;  the  electronic  device  detects  the  number  of  rotations  and counts the volume of water delivered.

M-BUS modules

M-BUS modules.
  • WMBR radio module wireless M-BUS
  • MBC wired module M-BUSs
  • B-i rml built-in radio module LoRaWAN™

Remote reading system for water meters with LoRaWAN fixed network

Remote reading system for water meters with LoRaWAN fixed network.
  • Water meters equipped with inductive sensor IPS
  • Transmitting radio module 868 MHz
  • Receiving portable antenna
  • PC (Client's own property)
  • Reading software.

WEF - Helical vane water meters WOLTMANN MID

WEF - Helical vane water meters WOLTMANN MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • In-line turbine woltmann meter, direct reading.
  • WEF-P REMOVABLE model, available in sizes from DN 50 to DN 300, temperature classes T50, measuring range R100 and R50, pre-set for remote reading.
  • WELF REMOVABLE model, available in sizes from DN 50 to DN 300, temperature classes T50, measuring range R100 and R50, fitted with sensor for remote reading.
  • Measuring insert replaceable without removing the water meter from the pipeline.
  • IP 68 DRY dial to use with hard, turbid and very calcareous waters.
  • All models are MID approved according to current Directive (modules B+D), in compliance with EN 14154, OIML R49 and ISO 4064 norms.
  • Requirements for upstream and downstream straight pipelines: U5/D3.
  • Installation in any position (for non horizontal installation, flow must be upwards): in any case, the meter must be always full of water to ensure a correct functioning.

Portable testing bench to check water meters installed in plumbing networks

Portable testing bench to check water meters installed in plumbing networks.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • For cold water, temperature class T30
  • Approvals:
    • water meter: CE MID MI001
    • electronic counter: UL508, CSA C22.2 No. 14, Lloyd
  • Water meter master Mod. PFML/20 for cold water, temperature class T30, Q3 4,0 m³/h, measuring range R160, fully equipped with reed pulse emitter, with pulse value of 1 pulse / 1 litre
  • Electronic counter with an 8 digit display, with external and manual resetting for litres reading ,self powered by a 7 years long life lithium pad battery
  • Upper housing made of shockproof lexan, sides and bottom made of metal with handle to carry
  • Threaded male fittings 3/4” GAS
  • Clear plastic cover allows direct master meter reading of m³ and its submultiples

Water meters for IRRIGATION and for FIRE PREVENTION

Water meters for IRRIGATION and for FIRE PREVENTION.
  • WEI Woltmann meter for not filtered water, at free passage, for irrigation applications
  • Model WEI DN 50...300, version with cast iron internal and external epoxy painted body, flanges PN 10 or PN 16
  • Designed for use with irrigation water, not filtered water, even with small suspended particles, directly from reservoir, canals, rivers and artesian wells
  • Transmission of movement through a magnetic joint
  • 360° rotating dumpproof dial - direct reading on numbered drums
  • The water flow through the meter at free passage, reduces head losses at their lowest; the small straight wings turbin, of tangential type, is only partially submerged in water
  • Removable measuring insert
  • Temperature class T30
  • Horizontal, inclined and vertical installation
  • Pre-arranged counter for reed pulse generator
  • Locable metallic lid
  • Available on request models with MID approval from DN 50 to DN 200

Water treatment

Water treatment.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Water meters equipped with an impulse-emitting device (all models can also be supplied just with pre-arrangement for impulse-emitting device)
  • Accuracy class: 2
  • BFUL model from DN. 15 to DN. 40 single jet – wet dial – temp. classes T30 e T50
  • PFUL model from DN. 15 to DN. 40
  • single jet – liquid-filled sealed counter – temp. classes T30 e T50
  • SFUL and AFUL models from DN. 15 to DN. 40 single jet – dry dial – temp. classes T30 e T50
  • SCUL and ACUL models from DN. 15 to DN. 40 single jet – dry dial – temp. classes T70 e T90
  • BFML model from DN. 15 to DN. 50 multi jet – wet dial – temp. classes T30 e T50
  • PFML model from DN. 15 to DN. 50 multi jet – liquid-filled sealed counter – temp. classes T30 e T50
  • AFML model from DN. 15 to DN. 50 multi jet – dry dial – temp. classes T30 e T50
  • ACML model from DN. 15 to DN. 50 multi jet – dry dial – temp. classes T70 e T90
  • WELF model from DN. 50 to DN. 300
  • helical vane (Woltmann) – dry dial – cold water up to 50°C
  • WELC model from DN. 50 to DN. 30 helical vane (Woltmann) – dry dial – hot water up to 130°C

CACML - Multi-jet flow sensor suitable for heating purposes

CACML - Multi-jet flow sensor suitable for heating purposes

MID MI001 APPROVAL

MID MI001 APPROVAL

  • flow sensor suitable for heating purposes, multi-jet, dry dial, for temperature up to 130 °C;

  • mod. CACML DN 15/20/25/32/40/50;
  • MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.

WELC - Woltmann flow sensor suitable for heating purposes

WELC - Woltmann flow sensor suitable for heating purposes

MID MI004 APPROVAL

MID MI004 APPROVAL

  • flow sensor suitable for heating purposes, WOLTMANN helical vane, dry dial for temperature up to 130 °C;
  • mod. WELC DN 50/65/80/100/125/150/200/250/300;
  • MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.

UC - Electronic counter for thermal energy

UC - Electronic counter for thermal energy

MID MI001 APPROVAL

MID MI001 APPROVAL

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

M-Bus

M-Bus

  • model UC:
    • remote electronic counter to connect to a mechanic, ultrasonic, electromagnetic meter installed over a return pipe; it is suitable to measure the thermal energy on heating and cooling systems;
    • digital display with 8 digits plus special characters;
    • powered by 10 years+1 lithium battery or optionally by 220V external supply or by M-Bus supply;
    • optical communication with M-Bus protocol;
    • data retrieve via single key on 3 (main/technical/stastics) levels installation on DIN rail, on plastic housing or wall mounting;
    • 2 additional pulse input to manage 2 reed switch pulsed hot/cold sanitary water meters  via internal terminal block with quick connections.
  • model UCB:
    • same features as model UC fitted with Mbus output with  protocol according to standard EN 1434-3 and EN 13757-2;
    • power suppy via M-Bus system  with unlimited number of readings for each device.
  • model UC2:
    • with output for volume and energy;
    • it is not possible to have M-Bus output and pulse inputs.
  • model UCBR:
    • with Wireless M-Bus interface;
    • communication based on Opening Metering System standard (OMS), open system to ensure a common transmission standard among various meters (water, gas, heat, electricity);
    • it is possible to change the default setting via a specific  optical head setting software (as option).
  • optional on all models:
    • double recording for cooling/heating consumption.
  • MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.

COMPACT2 - COMPACT2 DN 15 and DN 20

COMPACT2 - COMPACT2 DN 15 and DN 20

MID MI001 APPROVAL

MID MI001 APPROVAL

M-Bus Wireless

M-Bus Wireless

OMS - Open Metering System

OMS - Open Metering System

M-Bus

M-Bus

  • Compact electronic heatmeter, suitable for heat consumption measurements for central heating/cooling applications, and for hot water production sites
  • Mid Directive 2014/32/EU, annex MI004
  • Accuracy class EN 1434 Class 2
  • Electromagnetic Class E1/Mechanical class M1
  • lectronic Unit Protection Class IP65
  • The meter is made of 03 main units: ultrasonic flow sensor, split electronic unit (85cm), pair of temperature sensors (1 inserted in the body, 1 loose)
  • Bi-directional inductive detection (reverse flow) and air presence
  • Powered by 3V lithium battery (replaceable), estimated duration of 10 years depending on environmental/working conditions or preset for external electrical power
  • Possible installation on delivery pipes through software configuration
  • Available version for high temperature for district heating (130°max)

COMPACT2 - SONIK

COMPACT2 - SONIK

MID MI001 APPROVAL

MID MI001 APPROVAL

M-Bus Wireless

M-Bus Wireless

OMS - Open Metering System

OMS - Open Metering System

M-Bus

M-Bus

  • Compact electronic heatmeter, suitable for heat consumption measurements for central heating/cooling applications, and for hot water production sites
  • Mid Directive 2014/32/EU, annex MI004
  • Accuracy class EN 1434 Class 3
  • Electromagnetic Class E1/Mechanical class M1
  • Electronic Unit Protection Class IP65
  • The meter is made of 03 main units: single jet flow sensor, split electronic unit (50cm), pair of temperature sensors (1 inserted in the body, 1 loose)
  • Bi-directional inductive uptake (reverse flow)
  • Powered by 3V lithium battery (replaceable), estimated duration of 10 years depending on environmental/working conditions or preset for external electrical power;
  • Possible installation on delivery pipes through software configuration
  • Possible software configuration (without approval) for use with glycols for type and percentage with energy value ≤10 kWh

SONIK HEAT - Thermal energy ultrasonic meter

SONIK HEAT - Thermal energy ultrasonic meter

MID MI001 APPROVAL

MID MI001 APPROVAL

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

M-Bus

M-Bus

  • thermal energy ultrasonic meter, for temperature up to 130 °C;

  • model SONIK HEAT THREADED DN 15/20/25/40;
  • model SONIK HEAT FLANGED DN 25/40/50/65/80/100;
  • MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434 (only heating version).

Heating accessories

Heating accessories.
  • Pt temperature sensors, wet and dry mounting of sensor, OR gaskets, copper gaskets, bushings, brass mounts.

RSR - Electronic heat cost allocator

RSR - Electronic heat cost allocator RSR - Electronic heat cost allocator

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

  • electronic heat allocators in compact or remote sensor version for the distribution of heat consumption on radiators for central heating systems, or where it is not possible to use a metering system to correctly and fairly distribute heating costs of each individual flat;
  • integrated W-MBUS interface in S1 or T1 mode(standard), 868Mhz frequency, according to DIN EN13757-4, AES128 encryption;
  • optical interface for parameterization and reading of data via IR optical head and related software;
  • the heat allocator in combination with a thermostatic or a chrono-thermostatic control head allows to implement a system for temperature control and consumption accounting;
  • several kits available for installation on different types of existing radiators and convector heaters;
  • approved according to HKVO, EN834 – Norm DIN EN834 (Nov.1994) DIN EN 13757-4.

Remote reading for consumption measurement: Datalogger wireless M-Bus DL-WMBUS

Remote reading for consumption measurement: Datalogger wireless M-Bus DL-WMBUS

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

  • Working as DATALOGGER both through radio and through cable
  • Connection through Ethernet to read consumption data on web page
  • It manages up to 500 meters (see table enclosed in data sheet)
  • It is equipped with a graphical display (multi language to set up with tactile membrane key) to access data and status of local I/O
  • It is available with a remote antenna with 1,5 mt cable

Remote reading for consumption measurement: Wireless M-Bus repeater R-WMBUS

Remote reading for consumption measurement: Wireless M-Bus repeater R-WMBUS.

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

  • Radio signal repeater from meter /heat allocator to datalogger DL-WMBUS
  • It is fitted with MESH interface and supports multi-hop to receive and transmit the data
  • It can be mounted directly on the wall through screws and, as option, can be mounted on a stand through a specific mounting kit
  • The received signals are transmitted immediately without variable time-shifting

Remote reading for consumption measurement: Level Converter M-Bus LC61

Remote reading for consumption measurement: Level Converter M-Bus LC61.

M-Bus

M-Bus

  • For local reading of M-Bus cable networks
  • It can manage up to 60 physical devices M-Bus slaves
  • It can be used as a repeater in order to unlimited extend an existing M-Bus network via a serial connection of twin modules on a 35mm DIN rail EN 60529 or as a signal amplifier/regenerator for long distances
  • Local memory not available
  • Power supply 24 Vac/dc

Remote reading for consumption measurement: Rtu Datalogger M-Bus wired DL-LC61

Remote reading for consumption measurement: Rtu Datalogger M-Bus wired DL-LC61.

M-Bus

M-Bus

  • For remote reading of meters connected to the LEVEL CONVERTER M-BUS LC61
  • Working as wired DATALOGGER
  • It manages up to 250 wired meters by adding M-Bus LC61 level converter modules
  • Connection through Ethernet to read consumption data on web page
  • It is equipped with a graphical multi language display to set up via a tactile membrane key
  • Internal memory for storage of daily readings up to 10 years/ 1 year for intra-day data coming from wired meters
  • Reading frequency via cable: from 15 min to 24 hours intervals
  • 12-24V ac/dc power supply or Power over Ethernet (PoE)
  • Mounting by 35mm DIN rail (EN 60715)

Remote reading for consumption measurement: Pulse adaptor AI03

Remote reading for consumption measurement: Pulse adaptor AI03

M-Bus

M-Bus

  • Pulse adaptor allows the use of up to 2 meters, to connect separately
  • Suitable to translate a reed contact into a signal for M-Bus networks
  • Wall mounting
  • W x H x D (80 x 80 x 52) mm
  • Protective class IP54

Remote reading for consumption measurement: Modem MD02

Remote reading for consumption measurement: Modem MD02.

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

  • Modem with wireless connection to datalogger DL-WMBUS and ethernet connection to datalogger DL-LC61
  • UMTS and GSM quadband compact router / modem
  • Working through SIM data for mobile service
  • High speed to transfer HSPA data up to 21 Mbps DL and 5,76 Mbps UL
  • Very reliable connection to internet (Auto reboot in case of lost connection)
  • LAN and WIFI (4 ethernet gates) interfaces
  • Power supply AC/DC 100-240 Vac -> 9Vdc with wall supply

Remote reading for consumption measurement: Portalle receiver wireless M-Bus RPWMB

Remote reading for consumption measurement: Portalle receiver wireless M-Bus RPWMB.

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

  • Walk-by RECEIVER
  • Range up to 100 mt free field/20mt in buildings (depending from the building type and electromagnetic polluting conditions)
  • USB interface to connect via cable to a portable notebook
  • Communication via COM virtual gate
  • Compliance to Wireless M-Bus EN 13757-4:2013 standard
  • Supporting OMS standard (Opening Metering System)

Remote reading for consumption measurement: Software wireless M-BUS 1.1

Remote reading for consumption measurement: Software wireless M-BUS 1.1.
  • Working with Windows programs (Xp/Vista/7/8)
  • Windows minimum requirements: 1 MB RAM/13 MB free space on hard-disk
  • Suitable hardware:
    • Receiver USB RPWMB to receive/analyse wireless protocols coming from:
      • Heat cost allocator
      • Compact radio
      • Super-Dry with radio M-Bus module
      • Ultrasonic radio
    • Optical head with OT-USB cable for local I/O set up and reading:
      • Heat cost allocator
      • Compact radio
      • Super-Dry with radio M-Bus module
      • Ultrasonic radio

AFM - ACM - Multi-jet water meters MULTY MID

AFM - ACM - Multi-jet water meters MULTY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Multi-jet turbine straight reading meter, DRY dial, for turbid and calcareous water.
  • Mod. AFM-R100H, measuring range R100H, temperature classes T30 and T50.
  • Mod. ACM-R100H, measuring range R100H, temperature classes T70 and T90.
  • U0-D0: straight pipe not required upstream or downstream the meter.
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial.
  • All models are MID approved according to the European Directive 2004/22/CE (module B+D) and in compliance with the norms EN 14154, ISO 4064 and OIML R49, reaching an R (Q3/Q1) ≤ 100H.
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/ 2004 in compliance with European Directive 98/83 CE (Drinking Water Directive).
  • All models, on request, can be supplied pulsed output or preset for remote reading.

Remote reading system for water meters with walk-by/drive-by with LoRa network

Remote reading system for water meters with walk-by/drive-by with LoRa network.

Remote reading system for water meters equipped with LoRaWAN™ interface radio module with LoRa for walk-by/drive-by systems

Smart Metering G2-RF-SLW

Smart City G2-SC-SLW

MID MI001 APPROVAL

MID MI001 APPROVAL

Radio modules with a frequency of 868 Mhz, with the possibility of simultaneously transmitting the data of 1 or 2 meters, with the protocols listed below.
Radio module Mod. G2-RF-SLW.
LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by.
Radio module Mod. G2-RF-WMB.
W-Mbus OMS protocol for Walk-by/Drive-by.
Radio module Mod. G2-RF-W+L.
LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by +.
W-Mbus OMS protocol for Walk-by/Drive-by.

Smart Meter model QDFM-R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model QDFM-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by

Smart Meter model QDFM-R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model QDFM-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

Direct reading smart meter with data transmission via radio frequency 868 Mhz, with the protocols listed below.

  • Counter with radio module Mod. QDFM-R-CLW LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by.
  • Counter with radio module Mod. QDFM-R-WMB W-Mbus OMS protocol for Walk-by/Drive-by.
  • Counter with radio module Mod. QDFM-R-W+L LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by + W-Mbus OMS protocol for Walk-by/Drive-by: the system automatically switches between fixed network and Walk-by/Drive-by protocols.
  • Single jet counter, with protected rollers and fully protected dry dial, with mechanical transmission, R200H R63V, UO-D0, T50.
  • All models can be equipped with serial number and corresponding bar code or Qr code indelibly engraved on the dial and on the radio label.
  • Inductive transmission between mechanical and electronic parts. The radio module can be replaced.
  • All models are MID-approved in accordance with the current Directive.
  • All models are certified for use with drinking water according to D.M. 174 of 6/4/2004.
  • Transmitted consumption data, net compensated for any reverse flows.
  • Multi-level cryptographic data security.
  • Transmitted data: sensor ID, consumption data, hardware status, alarms, battery level, leaks.
  • Data security via multi-level encryption.
  • Modification of configuration data possible from fixed network remotely and/or via radio terminal.
  • Resin-coated IP 68 module for outdoor use - CE certified.

Smart meter model QDFU-R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model QDFU-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by

Smart meter model QDFU-R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model QDFU-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

Smart Volumetric Model VSF -R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model VSF-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by and model VSF-R-W+L LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by + W-Mbus OMS protocol for Walk-by/Drive-by: the system automatically switches between fixed network and Walk-by/Drive-by protocols.

Smart Volumetric Model VSF -R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model VSF-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

VOLUMETRIC Smart meter, rotary piston, direct reading with data transmission via radio frequency 868 Mhz, with the protocols listed below.

  • Meter with radio module Mod. VSF-R-CLW LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by.
  • Counter with radio module Mod. VSF-R-WMB W-Mbus OMS protocol for Walk-by/Drive-by.
  • Counter with radio module Mod. VSF-R-W+L LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by + W-Mbus OMS protocol for Walk-by/Drive-by: the system automatically switches between fixed network and Walk-by/Drive-by protocols.
  • With sizes DN 15 and DN 20, dry dial, for clean water, temperature class T50.
  • All models are MID-approved according to the current Directive (module B+D), in compliance with EN 14154 and OIML R49, achieving an R (Q3/Q1) ≤ 1000.
  • U0-D0: no straight pipework upstream and downstream of the meter required.
  • All models are certified for use with drinking water according to D.M. 174 of 6 April 2004.
  • Transmitted Data: Sensor ID, consumption data, hardware status, alarms, battery level, leaks.
  • Transmitted consumption data, net compensated for any reverse flows.
  • Multi-level cryptographic data security.
  • Transmitted data: Sensor ID, consumption data, hardware status, alarms, battery level, losses.
  • Data security via multi-level encryption.
  • Modification of configuration data possible from fixed network remotely and/or via radio terminal.
  • Resin-coated IP 68 module for outdoor use - CE certified.

Smart meter model WEF-R-CLW with LoraWAN protocol for fixed network and LoRa for walk-by/drive and model WEF-R-CWMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by

Smart meter model WEF-R-CLW with LoraWAN protocol for fixed network and LoRa for walk-by/drive and model WEF-R-CWMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

Direct reading smart meter with data transmission via radio frequency 868 Mhz, with the protocols listed below.

  • Counter with radio module Mod. WEF-R-CLW LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by.
  • Counter with radio module Mod. WEF-R-WMB W-Mbus OMS protocol for Walk-by/Drive-by.
  • Counter with radio module Mod. WEF-R-W+L LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by + W-Mbus OMS protocol for Walk-by/Drive-by.
  • W-Mbus OMS protocol for Walk-by/Drive-by: the system automatically switches between fixed network and Walk-by/Drive-by protocols.
  • Whirlpool meter, gauges DN 50 to DN 200, temperature class T50, measuring range R80H Internal measuring mechanism can be inspected without removing the meter from the system - with DRY dial for turbid and strongly calcareous water.
  • Inductive transmission between mechanical and electronic parts. Radio module can be replaced.
  • All models are MID-approved according to the applicable directive (module B+D), in accordance with EN 14154, OIML R49 and ISO 4064.
  • Requirements for straight pipe sections: U0/D0.
  • Installation permitted in any position (for non-horizontal installations, flow must be upwards.
  • Transmitted consumption data, net compensated by possible reverse flows.
  • Multi-level cryptographic data security.
  • Transmitted data: sensor ID, consumption data, hardware status, alarms, battery level, leaks.
  • Data security via multi-level encryption.
  • Modification of configuration data possible from fixed network remotely and/or via radio terminal.
  • Resin-coated IP 68 module for outdoor use - CE certified.

Smart reading radio model mod. G2-RF-SLW with LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by and radio module mod. G2-RF-WMB frequency 868 Mhz with W-Mbus OMS protocol for Walk-by / Drive-by

Smart reading radio model mod. G2-RF-SLW with LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by and radio module mod. G2-RF-WMB frequency 868 Mhz with W-Mbus OMS protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

Radio modules 868 Mhz radio frequency, transmittion protocols LoRaWAN-LoRa and W-Mbus OMS, with option to collect and transmit data from 1 or 2 water meters.

Portable receiver wireless M-BUS RPWMB

Portable receiver wireless M-BUS RPWMB.

  • Walk-by RECEIVER
  • Range up to 100 mt free field/20mt in buildings (depending from the building type and electromagnetic polluting conditions)
  • USB interface to connect via cable to a portable notebook
  • Communication via COM virtual gate
  • Compliance to Wireless M-Bus EN 13757-4:2013 standard
  • Supporting OMS standard (Opening Metering System)
  • It can manage bidirectional transmission of specifically pre-set devices
  • It can manage an AES 128 data cryptography

Newly developed VOLUMETRIC VSF meter, R ≤ 1000, plastic or brass case, preset for inductive output for radio remote reading.

VSF model

VOLUMETRIC COUNTER, rotating piston, direct reading

Newly developed mod. VSF DN 15 DN 20, dry dial, for clean water, temperature class T50, ensuring:

- Maximum quietness (< 20dB)

- Reduced overall dimensions

- Filter system for high resistance of suspended particles

All models are MID approved according to the current Directive (module B+D), in compliance with UNI EN ISO 4064 and OIML R49, achieving an R (Q3/Q1) ≤ 1000 in all positions

U0-D0: no straight pipe sections are required upstream and downstream of the meter

All models are certified for use with drinking water according to D.M. 174 of 6 April 2004

UNB/ UNP/ UNI - Single-jet water meters UNY MID

MID MI001 APPROVAL

MID MI001 APPROVAL

Single jet meter, direct reading, temperature classes T30 and T50

Mod. UNB, WET dial, DN 15- measuring range R315H,  DN 25-32, measuring range R160H, for clean water

Mod. UNP, LIQUID FILLED SEALED counter type, DN 15-20 measuring range R315H, DN 25-32, measuring range R160H, for turbid water

Mod.UNI, FULLY PROTECTED DRY dial,  DN 15-20 measuring range R315H,  DN 25-32, measuring range R160H, for turbid water

U0-D0: no straight pipe sections are required upstream and downstream of the meter

All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial

All models are MID approved according to the current Directive and in compliance with EN ISO 4064 and OIML R49, achieving an R (Q3/Q1) ≤ 315 H - ≤ 160 V

All models are certified for use with drinking water according to D.M. 174 of 6 April 2004 and  the UNP  and UNI models are ACS certified according to DGS/SD7A standard no. 571 of 2002

All models, on request, can be supplied with a pulse emitter or preset for remote reading

US-R-W+L- MID Ultrasonic Flow Meters

Ultrasonic meter suitable for domestic and commercial outdoor applications, static measuring technology with no moving parts

Mod. US-R-W+L with sizes DN 15 to DN 50, temperature class T30/T50, measuring range in all positions R250 - R500 (max) available on request. Degree of protection: IP 68 resin-coated

Integrated wireless communication with LoraWAN/ W-Mbus OMS protocols with automatic switch and with NBIot protocol

Two-way measurement

Large LCD display showing total volume, instantaneous flow rate, battery indicator, alarms, flow direction, water temperature, test display

Delivered volume display options: net, forward flow only, alternating forward/reverse

Battery life >13 years, under normal conditions of use, depending on radio protocol

Data logger function with NFC module on request

Local communication: optical port

Wear-resistant brass body, threaded connections

U0-D0: no straight pipe sections upstream and downstream of the meter are required

All models are certified for use with potable water according to D.M. 174 of 6/4/2004

All models are MID-approved according to the current Directive (module B+D), in accordance with OIML R49 and ISO 4064

Smart meter model QDFM-R-CN-BIOT with data transmission via fixed cellular network Bi-Iot standard

Smart meter with radio module Mod. QDFM-R-CNB-IOT

Multiple jet meter, with fully protected dry dial, with mechanical transmission, R200H R63V, UO-D0, T50

All models can be fitted with a serial number and barcode or Qr code indelibly engraved on the dial and radio label

Inductive transmission between mechanical and electronic parts. The radio module can be replaced