Water meters, heat meters and radio remote reading systems, smart meters.
Wireless solutions IOT: radio applications.

 
  • QDFM - PI.

    QDFM: R160H, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial

    QDFM-R160, (on request models from R10 to R250), LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, measuring range R160, accuracy class 2, environmental class C, for turbid waters.

  • QDFU PI.

    QDFU: R200H-R100V, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial

    QDFU-R200H-R100V R100V (on request models from R10 to R250), measuring range R200H-R100V, accuracy class 2, environmental class C, for turbid water.

  • AFMS-PI.

    AFMS-PI.

    Multi-jet turbine straight reading meter, for turbid and calcareous water.

  • RF-SLW.

    RF-SLW.

    AMR systems.

Smart meters and data transmission systems

Smart Meter model QDFM-R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model QDFM-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by

Smart Meter model QDFM-R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model QDFM-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

Direct reading smart meter with data transmission via radio frequency 868 Mhz, with the protocols listed below.

  • Counter with radio module Mod. QDFM-R-CLW LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by.
  • Counter with radio module Mod. QDFM-R-WMB W-Mbus OMS protocol for Walk-by/Drive-by.
  • Counter with radio module Mod. QDFM-R-W+L LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by + W-Mbus OMS protocol for Walk-by/Drive-by: the system automatically switches between fixed network and Walk-by/Drive-by protocols.
  • Single jet counter, with protected rollers and fully protected dry dial, with mechanical transmission, R200H R63V, UO-D0, T50.
  • All models can be equipped with serial number and corresponding bar code or Qr code indelibly engraved on the dial and on the radio label.
  • Inductive transmission between mechanical and electronic parts. The radio module can be replaced.
  • All models are MID-approved in accordance with the current Directive.
  • All models are certified for use with drinking water according to D.M. 174 of 6/4/2004.
  • Transmitted consumption data, net compensated for any reverse flows.
  • Multi-level cryptographic data security.
  • Transmitted data: sensor ID, consumption data, hardware status, alarms, battery level, leaks.
  • Data security via multi-level encryption.
  • Modification of configuration data possible from fixed network remotely and/or via radio terminal.
  • Resin-coated IP 68 module for outdoor use - CE certified.

Smart meter model QDFU-R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model QDFU-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by

Smart meter model QDFU-R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model QDFU-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

Smart Volumetric Model VSF -R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model VSF-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by and model VSF-R-W+L LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by + W-Mbus OMS protocol for Walk-by/Drive-by: the system automatically switches between fixed network and Walk-by/Drive-by protocols.

Smart Volumetric Model VSF -R-CLW with LoRaWan protocol for fixed network and LoRa for Walk-by / Drive-by and model VSF-R-WMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

VOLUMETRIC Smart meter, rotary piston, direct reading with data transmission via radio frequency 868 Mhz, with the protocols listed below.

  • Meter with radio module Mod. VSF-R-CLW LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by.
  • Counter with radio module Mod. VSF-R-WMB W-Mbus OMS protocol for Walk-by/Drive-by.
  • Counter with radio module Mod. VSF-R-W+L LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by + W-Mbus OMS protocol for Walk-by/Drive-by: the system automatically switches between fixed network and Walk-by/Drive-by protocols.
  • With sizes DN 15 and DN 20, dry dial, for clean water, temperature class T50.
  • All models are MID-approved according to the current Directive (module B+D), in compliance with EN 14154 and OIML R49, achieving an R (Q3/Q1) ≤ 800.
  • U0-D0: no straight pipework upstream and downstream of the meter required.
  • All models are certified for use with drinking water according to D.M. 174 of 6 April 2004.
  • Transmitted Data: Sensor ID, consumption data, hardware status, alarms, battery level, leaks.
  • Transmitted consumption data, net compensated for any reverse flows.
  • Multi-level cryptographic data security.
  • Transmitted data: Sensor ID, consumption data, hardware status, alarms, battery level, losses.
  • Data security via multi-level encryption.
  • Modification of configuration data possible from fixed network remotely and/or via radio terminal.
  • Resin-coated IP 68 module for outdoor use - CE certified.

Smart meter model WEF-R-CLW with LoraWAN protocol for fixed network and LoRa for walk-by/drive and model WEF-R-CWMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by

Smart meter model WEF-R-CLW with LoraWAN protocol for fixed network and LoRa for walk-by/drive and model WEF-R-CWMB freq.868 Mhz with W-Mbus protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

Direct reading smart meter with data transmission via radio frequency 868 Mhz, with the protocols listed below.

  • Counter with radio module Mod. WEF-R-CLW LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by.
  • Counter with radio module Mod. WEF-R-WMB W-Mbus OMS protocol for Walk-by/Drive-by.
  • Counter with radio module Mod. WEF-R-W+L LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by + W-Mbus OMS protocol for Walk-by/Drive-by.
  • W-Mbus OMS protocol for Walk-by/Drive-by: the system automatically switches between fixed network and Walk-by/Drive-by protocols.
  • Whirlpool meter, gauges DN 50 to DN 200, temperature class T50, measuring range R80H Internal measuring mechanism can be inspected without removing the meter from the system - with DRY dial for turbid and strongly calcareous water.
  • Inductive transmission between mechanical and electronic parts. Radio module can be replaced.
  • All models are MID-approved according to the applicable directive (module B+D), in accordance with EN 14154, OIML R49 and ISO 4064.
  • Requirements for straight pipe sections: U0/D0.
  • Installation permitted in any position (for non-horizontal installations, flow must be upwards.
  • Transmitted consumption data, net compensated by possible reverse flows.
  • Multi-level cryptographic data security.
  • Transmitted data: sensor ID, consumption data, hardware status, alarms, battery level, leaks.
  • Data security via multi-level encryption.
  • Modification of configuration data possible from fixed network remotely and/or via radio terminal.
  • Resin-coated IP 68 module for outdoor use - CE certified.

Portable receiver wireless M-BUS RPWMB

Portable receiver wireless M-BUS RPWMB.

  • Walk-by RECEIVER
  • Range up to 100 mt free field/20mt in buildings (depending from the building type and electromagnetic polluting conditions)
  • USB interface to connect via cable to a portable notebook
  • Communication via COM virtual gate
  • Compliance to Wireless M-Bus EN 13757-4:2013 standard
  • Supporting OMS standard (Opening Metering System)
  • It can manage bidirectional transmission of specifically pre-set devices
  • It can manage an AES 128 data cryptography

Smart reading radio model mod. G2-RF-SLW with LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by and radio module mod. G2-RF-WMB frequency 868 Mhz with W-Mbus OMS protocol for Walk-by / Drive-by

Smart reading radio model mod. G2-RF-SLW with LoRaWAN protocol for fixed network and LoRa for Walk-by/Drive-by and radio module mod. G2-RF-WMB frequency 868 Mhz with W-Mbus OMS protocol for Walk-by / Drive-by.

MID MI001 APPROVAL

MID MI001 APPROVAL

Radio modules 868 Mhz radio frequency, transmittion protocols LoRaWAN-LoRa and W-Mbus OMS, with option to collect and transmit data from 1 or 2 water meters.

LoRaWAN radio protocol module for fixed network and LoRa for walk-by/drive-by model G2-IPS-CLW

LoRaWAN radio protocol module for fixed network and LoRa for walk-by/drive-by model G2-IPS-CLW.
  • Inductive Sensor with LoRaWANTM radio module available in compact version for multiple and single jet water meters with wet dial, liquid filled counter type, fully protected dial, and super dry dial MID approved, preset for inductive sensor in K1. The measurement of the water is done by conveying the flow rate into a rotation of a star index fitted with an not magnetic metallic disk placed on the water meter dial.

868 wireless M-bus radio module module G2-IPS-C868WMB

868 wireless M-bus radio module module G2-IPS-C868WMB.
  • Inductive Sensor with 868 Mhz Wireless M-Bus available in compact version for multiple and single jet water meters with wet dial, liquid filled counter type, fully protected dial, and super dry dial MID approved, preset for inductive sensor in K1. The measurement of the water is done by conveying the flow rate into a rotation of a star index fitted with an amagnetic metallic disk placed on the water meter dial; the electronic device detects the number of rotations and counts the volume of water delivered.

NB-IoT radio module

NB-IoT radio module.
  • Inductive   Sensor   with   embedded   radio  module   NB-IoTavailable  in  compact  version  for  multiple  and  single  jet water  meters  with  wet  dial,  liquid  filled  counter  type,  fully protected dial, and super dry dial MID approved, preset for inductive sensor in K1. The measurement  of  the  water is done by  conveying  the  flow  rate  into  a  rotation  of a  star  index  fitted with  an  amagnetic  metallic  disk placed  on  the  water  meterdial;  the  electronic  device  detects  the  number  of  rotations  and counts the volume of water delivered.

M-BUS modules

M-BUS modules.
  • WMBR radio module wireless M-BUS
  • MBC wired module M-BUSs
  • B-i rml built-in radio module LoRaWAN™

Remote reading system for water meters with LoRaWAN fixed network

Remote reading system for water meters with LoRaWAN fixed network.
  • Water meters equipped with inductive sensor IPS
  • Transmitting radio module 868 MHz
  • Receiving portable antenna
  • PC (Client's own property)
  • Reading software.

Remote reading system for water meters with walk-by/drive-by with LoRa network

Remote reading system for water meters with walk-by/drive-by with LoRa network.

Remote reading system for water meters equipped with LoRaWAN™ interface radio module with LoRa for walk-by/drive-by systems

Thermo "Portable"

Termo

MID MI001 APPROVAL

MID MI001 APPROVAL

Infrared technology frontal thermometer for instant VERIFICATION of body temperature without contact
Ideal for checking people's temperature during access to facilities where it is necessary to give a PASS - DO NOT PASS to authorise entry.
Portable" model with read-out button and display indication of temperature and access status.
Product conforms to EC directive according to EMC directive electromagnetic compatibility.