Water meters, heat meters and radio remote reading systems, smart meters.
Wireless solutions IOT: radio applications.


G2 Colombia

 
  • VSF R1000.

    R1000 volumetric smart meter.

  • us

    Ultrasonic meter suitable for domestic and commercial outdoor applications, static measuring technology with no moving parts.
    Mod. US sizes DN 15 to DN 50 temperature class T30/T50, measuring range up to R500 Protection class: resin-coated IP68.

  • AFMS-PI.

    AFMS-PI.
    Super-Dry model temperature classes T30 and T50 (models up to R200 available on request).

  • RF-SLW.

    RF-SLW.
    AMR systems.

  • QDFM - PI.

    QDFM-, rollers protected, dry dial fully protected, measuring range R160 (models up to R315 on request), accuracy class 2, environmental class C, for turbid water.

  • Smart Meter

    UNI: protected rollers, FULLY PROTECTED DRY dial measuring range R315H-R160V, accuracy class 2, environmental class -25 +55°C, for turbid water.

QDFUPI / QDFU - Single-jet water meters UNY MID

QDFUPI / QDFU - Single-jet water meters UNY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Single-jet meter, direct reading, temperature classes T30 and T50
  • Mod. QDFUPI-R200H-R100V, DN 15 – 20, preset K=1 for inductive sensor IPS proof from magnetic intereferences, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R200H-R100V, for  turbid water
  • Mod. QDFUPI-R160H-R40V, DN 25 – 32 – 40, preset K=1 for inductive sensor IPS proof from magnetic intereferences, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R160H-R40V, for turbid water
  • Mod. QDFU-R200H-R100V, DN 15 – 20, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R200H-R100V, for  turbid water
  • Mod. QDFU-R160H-R40V, DN 25 – 32 – 40, LIQUID FILLED SEALED counter, FULLY PROTECTED DRY dial, mechanical transmission, measuring range R160H-R40V, for turbid water
  • U0-D0: straight pipe not required upstream or downstream the meter
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial
  • All models are MID approved according to the European Directive 2004/22/CE (module B+D) and in compliance with the norms EN 14154 and OIML R49
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/2004
  • All models, on request, can be supplied pulsed output

BFU / BCU / PFU / PCU - Single-jet water meters UNY MID

BFU / BCU / PFU / PCU - Single-jet water meters UNY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Single-jet meter, direct reading
  • Mod. BFU-R100, WET DIAL, measuring range R100, temperature classes T30 and T50, for clean water
  • Mod. BFU-R160, WET DIAL, measuring range R160, temperature classes T30 and T50, for clean water
  • Mod. BCU-R80, WET DIAL, measuring range R80, temperature classes T70 and T90, for clean water
  • Mod. BCU-R160, WET DIAL, measuring range R160, temperature classes T70 and T90, for clean water
  • Mod. PFU-R100, LIQUID FILLED SEALED counter, measuring range R100, temperature classes T30 and T50, for turbid water
  • Mod. PFU-R160, LIQUID FILLED SEALED counter, measuring range R160, temperature classes T30 and T50, for turbid water
  • Mod. PCU-R80, LIQUID FILLED SEALED counter, measuring range R80, temperature classes T70 and T90, for turbid water
  • Mod. PCU-R160, LIQUID FILLED SEALED counter, measuring range R160, temperature classes T70 and T90, for turbid water
  • U0-D0: straight pipe not required upstream or downstream the meter
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial
  • All models are MID approved according to the European Directive 2004/22/CE (module B+D)  and in compliance with the norms EN 14154 and OIML R49, reaching an R (Q3/Q1) ≤ 200 H - ≤ 100 V                    
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/2004
  • All models, on request, can be supplied pulsed output or preset for remote reading

SFU / SCU / AFU / ACU - Single-jet water meters UNY MID

SFU / SCU / AFU / ACU - Single-jet water meters UNY MID.

MID MI001 APPROVAL

MID MI001 APPROVAL

  • Single-jet meter, direct reading.
  • DRY dial for turbid and greatly calcareous waters (mod.SFU/SCU are fitted with 360° rotating dial for easy reading, and on request, available with or without lid, with or without glass wiping).
  • Mod. SFU-R80, DN 15 – 20, temperature classes T30 and T50, measuring range R80.
  • Mod. SCU-R80, DN 15 – 20, temperature classes T70 and T90, measuring range R80.
  • Mod. AFU-R80, DN 25 – 32 – 40, temperature classes T30 and T50, measuring range R80.
  • Mod. ACU-R80, DN 25 – 32 – 40, temperature classes T70 and T90, measuring range R80.
  • U0-D0: straight pipe not required upstream or downstream the meter.
  • All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial.
  • All models are MID approved according to the current European Directive (module B+D) and in compliance with the norms EN 14154 and OIML R49, reaching an R (Q3/Q1) ≤ 125.
  • All models are certified for use with water for human consumption, according to the D.M. 174 of 6/4/ 2004 in compliance with European Directive 98/83 CE (Drinking Water Directive).
  • All models, on request, can be supplied pulsed output or preset for remote reading: reed, M-Bus, LoraWan.

UNB/ UNP/ UNI - Single-jet water meters UNY MID

MID MI001 APPROVAL

MID MI001 APPROVAL

Single jet meter, direct reading, temperature classes T30 and T50

Mod. UNB, WET dial, DN 15- measuring range R315H,  DN 25-32, measuring range R160H, for clean water

Mod. UNP, LIQUID FILLED SEALED counter type, DN 15-20 measuring range R315H, DN 25-32, measuring range R160H, for turbid water

Mod.UNI, FULLY PROTECTED DRY dial,  DN 15-20 measuring range R315H,  DN 25-32, measuring range R160H, for turbid water

U0-D0: no straight pipe sections are required upstream and downstream of the meter

All models can be customised with a serial number and its relevant barcode indelibly engraved on the dial

All models are MID approved according to the current Directive and in compliance with EN ISO 4064 and OIML R49, achieving an R (Q3/Q1) ≤ 315 H - ≤ 160 V

All models are certified for use with drinking water according to D.M. 174 of 6 April 2004 and  the UNP  and UNI models are ACS certified according to DGS/SD7A standard no. 571 of 2002

All models, on request, can be supplied with a pulse emitter or preset for remote reading